In the modern poultry industry, ensuring the safe, hygienic, and environmentally responsible disposal of broiler mortalities is a critical operational and ethical challenge. Improper handling poses significant risks of disease transmission and environmental pollution. Our advanced White chicken harmless treatment equipment for poultry farms provides a comprehensive solution, transforming a potential biohazard into a safe, sterile, and value-added resource like organic fertilizer or protein meal. This system is engineered for high-efficiency pathogen elimination, making it an essential Poultry pathogen-free processing device for chicken slaughterhouse and farm-level biosecurity infrastructure. The core of our technology lies in a fully automated, high-temperature, high-pressure sterilization process that ensures complete decontamination. Our integrated white chicken sterilization treatment system is designed for durability, energy efficiency, and minimal operator intervention, meeting the stringent sanitary standards required for large-scale poultry operations.
The Broiler sanitary disposal machinery operates on a meticulously engineered thermal hydrolysis principle. The process begins with automated loading, followed by a high-temperature sterilization phase under significant pressure. This critical step effectively destroys all pathogens, including viruses, bacteria, and spores, ensuring the output material is completely safe. After sterilization, the material undergoes a drying and grinding process, resulting in a fine, stable, and odorless powder. This final product is rich in nutrients, making it suitable for agricultural use as an organic soil amendment, closing the loop in a sustainable production cycle. The entire cycle is managed by an intuitive PLC control system, allowing for precise regulation of time, temperature, and pressure for consistent, verifiable results.
| Model | Capacity (kg/batch) | Processing Time (min/batch) | Power Supply | Steam Pressure (MPa) | Footprint (L*W*H meters) |
|---|---|---|---|---|---|
| BSD-500 | 500 | 90-120 | 380V / 50Hz / 3 Phase | 0.6 - 0.8 | 4.5*2.2*2.8 |
| BSD-1000 | 1000 | 120-150 | 380V / 50Hz / 3 Phase | 0.6 - 0.8 | 5.5*2.5*3.0 |
| BSD-2000 | 2000 | 150-180 | 380V / 50Hz / 3 Phase | 0.7 - 0.9 | 7.0*2.8*3.5 |
| Process Stage | Temperature Range | Pressure Range | Duration | Key Outcome |
|---|---|---|---|---|
| Heating & Sterilization | 140°C - 180°C | 0.5 - 0.9 MPa | 40-60 minutes | Complete pathogen destruction |
| Pressure Release & Drying | 100°C - 120°C | Atmospheric | 30-50 minutes | Moisture reduction |
| Crushing & Cooling | < 50°C | Atmospheric | 20-30 minutes | Final powder production |